ABR/ASSR dBnHL → dBeHL Corrections

Enter uncorrected thresholds (dBnHL). The page applies age-based correction factors to generate estimated dBeHL. No data is stored.

Patient details

Used with test date to compute chronological age.

Prematurity weeks = max(0, 40 − GA).

Defaults to today.

Important: ASSR uses subtract (dBeHL = dBnHL − CF). ABR uses add (dBeHL = dBnHL + CF). Inserts assumed. (Supra-aural rows ignored.) ABR BC click ≤12w uses CF = 0 by design.

ASSR (NB CE-Chirp, Inserts)

Correction factors depend on the entered dBnHL band (0/5, 10/15, … 100).

Air conduction

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

Bone conduction

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

ABR (Inserts)

ABR correction factors depend on corrected age bracket and stimulus type. (ABR uses ADD.)

Air conduction — Tone pip / Click

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

Air conduction — Chirp

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

Bone conduction — Tone pip / Click

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

Bone conduction — Chirp

Uncorrected threshold (dBnHL)

Corrected estimate (dBeHL)

Acronyms & definitions (expanded)